Densglass exterior rated wall detail
WebExterior Wall and Ceiling 18; Industrial & OEM 9; Interior Wall and Ceiling ... Benefits. Building Envelope 11; Ease-of-Use 18; Energy Efficient 7; Fire Rated 13; Fire Resistant 23; Hail Resistant 4; High Impact Resistant 6; Lightweight 14; Low ... DensGlass® 3; DensShield® 2; DryGuard ® 2 ... Webbeen changed to 3-hour rated (Wall Type C3A). See plan sheets A2.01 – A2.12. b) All exterior bearing walls on Type IIIA levels 3 – roof have been changed to 2-hour rated wall assemblies (E2A, E2D, and E2C). Wall Type E2A rated on both the interior and exterior sides complying with Table 601 for exterior bearing walls and 602 for fire ...
Densglass exterior rated wall detail
Did you know?
WebExterior Wall and Ceiling Industrial & OEM Interior Wall and Ceiling Roof Specialty Sub-Floor Benefits Building Envelope Ease-of-Use Energy Efficient Fire Rated Fire Resistant Hail Resistant High Impact Resistant Lightweight Low Impact Resistant Moisture Resistant Special Applications Vapor Permeability Versatility Wind Uplift Resistant Build Type WebMar 29, 2024 · You typically need to use one of the tested assemblies for a fire rated wall. The most common example would be a typical 1 hour wall, which would be 5/8" drywall on both sides, with wood or metal studs between. ... densglass is commonly available from commericial building supply houses. It's a commonly used product for exterior details in ...
WebArea Separation Wall - Georgia-Pacific Building Products. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space between liner panels and adjacent wood or metal framing. Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C ... WebThis detail shows block with flat ends being used at the vertical control joint. Fireproof material resides at the vertical CJ, along with sealant and backer rod. This detail allows shrinkage of the block, but does not resist lateral loads. There is horizontal joint reinforcement at 16″ o.c. vertically in the wall, interrupted at the CJ.
WebNov 2, 2024 · DensGlass® Sheathing is the #1 architecturally specified fiberglass mat gypsum sheathing 1. Helps add performance and durability to a wide range of fire-rated … Don’t leave the integrity of your exterior walls to chance. Rely on Georgia-Pacific … Engineered to prevent damage to the sub-floor or wall cavity if moisture seeps … DensGlass ® Sheathing disrupted the way commercial buildings are designed over … WebArea Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space on both sides must be maintained between liner panels and adjacent framing. Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C gypsum wallboard or ...
WebDensGlass ® Sheathing disrupted the way commercial buildings are designed over 30 years ago, and now DensElement ® Barrier System continues that legacy of innovation by integrating 3 products in one: gypsum sheathing, water-resistive barrier and air barrier. AquaKor™ Technology creates the WRB-AB within by integrating the fiberglass mat and …
WebFor fire-rated multifamily structures, choose DensElement® Barrier System. By filling microscopic voids in the glass mat and gypsum core via AquaKor™ Technology, a hydrophobic, monolithic surface is created that blocks bulk water while retaining vapor permeability. No additional air or water barrier is needed, saving time. shippingport post office hoursWebExterior Wood-Framed Wall Exterior Side: 5/8” (15.9 mm) DensGlass® Fireguard® Sheathing or ToughRock® Fireguard X® Sheathing applied vertically or horizontally to 2”x 4” wood studs 16” (406 mm) o.c. with 1-3/4” (45 mm) galvanized roofing nails 7” (178 mm) o.c. Exterior surface covered with weather exposed cladding or finish system. shippingport nuclear plantWebDec 4, 2024 · The required ratings range from 0 to 3 hours, depending on the corresponding fire separation distances that range from less than 5 feet to more than 30 feet. One example is an assembly occupancy type composed of type IIB building construction having nonbearing exterior walls. shippingport pennsylvania nuclear power plantWeb1. Fiberglass-Mat Faced Gypsum Sheathing: DensGlass Sheathing. 2. Fiberglass-Mat Faced Gypsum Sheathing, Type X for Fire Rated Designs: DensGlass Fireguard … shipping port problemsWebNow, you can specify our products in your Revit projects more easily than ever with the Georgia-Pacific BIM Library. Georgia-Pacific has partnered with BIMsmith to provide easy access to BIM for our industry-trusted line of products, including our Dens® family of high-performance fiberglass mat gypsum panels that are widely recognized by their GOLD color. shippingport power plantWebDensGlass 5/8-in 4-ft x 8-ft Mold Resistant Moisture Resistant Regular Drywall Panel Shop DensGlass 2 In Store Only Get Pricing and Availability Use Current Location Track record that spans more than 30 years Helps … quest diagnostics ocoee and walk insWeb9. SBC Table 602 - LVL 1 & 2/G2.01 - Revise the diagrams to show 1-hour rated construction at the east exterior walls. 10. SBC 704.3 - 7/A9.04 - GA File No. BM 1137 is a proprietary assembly. Revise the detail to specifically call out a proprietary GWB product from the referenced assembly. 11. quest diagnostics oklahoma city ok